Transformer Specifications Requirements

The transformer has to be:

24 Volt A.C. Class II

(This is a magnetic coil type -not electronic coil type)

Lantern Requirements:

The electronic ignition system for each lantern requires 12Va per lantern which is approximately 1/2 amp (.5) @ 24 volts per lantern.

Example:

A 24 volt A.C. 40Va ClassII transformer will operate one, two or three lanterns.

1 Lantern x 12 Va=12 Va  (Less than 40Va)

2 Lanterns x 12Va=24 Va (Less than 40Va)

3 Lanterns x 12Va=36 Va (Less than 40Va)

Available @ W.W. Grainger Stock #4X746

Available @ Johnstone Supply Stock #PF42440

A 24 Volt A.C. 50Va Class II transformer will operate four lanterns but not five.

4 Lanterns x 12 Va=48 Va (Less than 50Va)

5 Lanterns x 12 Va=60Va (Greater than 50 Va)